Design and Experiment of Fluid Dynamic Ultrasonic Water Aerator

In order to improve the efficiency of water aerator, based on Venturi experimental principle in hydraulics and fluid dynamic ultrasonic generator, the inlet section, throat section, and outlet section of reed whistle ultrasonic generator were designed, and the effect of the water aerator on dissolved oxygen was preliminarily studied. Results indicate that using this water aerator, the dissolved oxygen was 7.94 mg/L, exceeding the saturation value of dissolved oxygen (7.82 mg/L) at current water temperature, reaching the supersaturation. Therefore, the designed water aerator will have a bright application prospect in sewage treatment, aquaculture and aerated irrigation of plants.


Subject(s):
Issue Date:
2016-09
Publication Type:
Journal Article
PURL Identifier:
http://purl.umn.edu/250041
Published in:
Asian Agricultural Research, Volume 08, Issue 09
Page range:
60-63
Total Pages:
4




 Record created 2017-04-01, last modified 2017-06-09